Solventless sample preparation for pesticides analysis in environmental water samples using solid-phase microextraction-high resolution gas chromatography/mass spectrometry (SPME-HRGC/MS)

J Environ Sci Health B. 2003 Jul;38(4):417-28. doi: 10.1081/PFC-120021662.

Abstract

Solid-phase micro-extraction (SPME) coupled on line with high resolution gas chromatography and mass spectrometric detection is described for the analysis of pesticides in environmental water samples. Experiments were performed in order to optimize the SPME extraction conditions for selected pesticides including tiomethon, trichorfon, dimethoate, diazinon, malathion, dicofol, methidathion, ethion, bromopropylate and pyrazophos from spiked water solutions. To enhance the SPME efficiency, experimental conditions including the fiber composition, stirring rate, temperature, adsorption time, desorption time and salt concentration were optimized. After validation, the SPME-GC/MS methodology was applied to real-world environmental water samples.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acrylic Resins / chemistry
  • Adsorption
  • Dimethylpolysiloxanes / chemistry
  • Fresh Water / chemistry
  • Gas Chromatography-Mass Spectrometry / methods*
  • Mineral Fibers
  • Osmolar Concentration
  • Pesticide Residues / analysis*
  • Pesticide Residues / isolation & purification
  • Polyethylene Glycols / chemistry
  • Silicones / chemistry
  • Solvents
  • Temperature
  • Time Factors
  • Vinyl Compounds / chemistry
  • Water Pollutants, Chemical / analysis*
  • Water Pollutants, Chemical / isolation & purification

Substances

  • Acrylic Resins
  • Dimethylpolysiloxanes
  • Mineral Fibers
  • Pesticide Residues
  • Silicones
  • Solvents
  • Vinyl Compounds
  • Water Pollutants, Chemical
  • Polyethylene Glycols
  • carbopol 940
  • baysilon
  • divinyl benzene