Background: Expensive devices are increasingly used to close a patent fenestration after a modified Fontan operation. We report our 5-year institutional experience of clipped tube fenestration after extracardiac Fontan operation, which allows for simple transcatheter coil occlusion.
Methods: We retrospectively reviewed 30 children, median age of 4.0 years (range, 2.4 to 8.8 years) who underwent extracardiac Fontan operation between May 1996 and May 2001, and were fenestrated using a 4- to 8-mm diameter clipped tube graft.
Results: Ten children had a patent fenestration occluded by transcatheter placement of 15 detachable coils (5- to 8-mm diameter). Aortic oxygen saturations increased on average by 5.5% (2% to 14%) and mean pressures in the Fontan circuit by 2.5 mm Hg (0 to 3 mm Hg). Four had immediate complete occlusion angiographically and 6 had trivial residual shunt, but complete occlusion by echocardiography at follow-up. There have been no immediate complications, late coil embolizations, thromboembolic events, or documented hemolysis within a follow-up after coil implantation of 1.7 years (0.4 to 4.5 years). Spontaneous fenestration closure was documented in 8 patients at cardiac catheterization and 9 patients by echocardiography with consistent improvement in resting transcutaneous oxygen saturation. Two children with a patent fenestration have been considered inappropriate for closure, and there was one early surgical death. There have been no complications related to the tube fenestration modification within a follow-up postoperation of 2.6 years (0.1 to 5.5 years).
Conclusions: Clipped tube fenestration after extracardiac Fontan operation is a useful surgical modification that allows for simple transcatheter coil occlusion.