Unusual complication of surgical voice restoration

J Laryngol Otol. 2004 Feb;118(2):148-9. doi: 10.1258/002221504772784630.

Abstract

A case of oesophageal obstruction following the removal of a tracheoesophageal valve by division is presented. The obstruction was caused by impaction of a portion of the valve at a previously undiscovered benign oesophageal stricture. The obstruction was resolved by interventional radiology with no long-term sequelae. To the best of our knowledge this complication has not been described previously.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Carcinoma, Squamous Cell / surgery
  • Device Removal
  • Esophageal Stenosis / complications*
  • Esophageal Stenosis / pathology
  • Humans
  • Laryngeal Neoplasms / surgery
  • Larynx, Artificial* / adverse effects
  • Male
  • Postoperative Complications* / pathology
  • Prosthesis Failure
  • Reoperation