Sniff nasal inspiratory pressure: what is the optimal number of sniffs?

Eur Respir J. 2006 May;27(5):980-2. doi: 10.1183/09031936.06.00121305. Epub 2006 Feb 2.

Abstract

Sniff nasal inspiratory pressure (SNIP) measurement is a volitional noninvasive assessment of inspiratory muscle strength. A maximum of 10 sniffs is generally used. The purpose of the present study was to investigate whether the maximum SNIP improved after the tenth sniff. In total, 20 healthy volunteers and 305 patients with various neuromuscular and lung diseases were encouraged to perform 40 and 20 sniffs, respectively. The best SNIP among the first 10 sniffs was lower than the best SNIP among the next 10 sniffs in the healthy volunteers and patients. The SNIP improvement after the twentieth sniff was marginal. In conclusion, a learning effect persists after the tenth sniff. The current authors suggest using 10 additional sniffs when the best result of the first 10 sniffs is slightly below normal, or when sniff nasal inspiratory pressure is used to monitor a progressive decline in inspiratory muscle strength.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Child
  • Female
  • Humans
  • Inhalation / physiology*
  • Male
  • Nose / physiology*
  • Pressure
  • Respiratory Function Tests / methods
  • Respiratory Function Tests / statistics & numerical data
  • Respiratory Muscles / physiology*