Midterm results with thoracic endovascular aortic repair for chronic type B aortic dissection with associated aneurysm

J Thorac Cardiovasc Surg. 2011 Feb;141(2):322-7. doi: 10.1016/j.jtcvs.2010.10.043.

Abstract

Objective: Thoracic endovascular aortic repair for chronic type B aortic dissection with associated descending thoracic aneurysm remains controversial. Concerns include potential ischemic complications due to branch vessel origin from the chronic false lumen and continued retrograde false lumen/aneurysm sac pressurization via fenestrations distal to implanted endografts. The present study examines midterm results with thoracic endovascular aortic repair for chronic (>2 weeks) type B aortic dissection with associated aneurysm to better understand the potential role of thoracic endovascular aortic repair for this condition.

Methods: Between March 2005 and December 2009, 51 thoracic endovascular aortic repair procedures were performed at a single institution for management of chronic type B dissection. The indication for thoracic endovascular aortic repair was aneurysm in all cases. A subset of 7 patients (14%) underwent placement of the EndoSure wireless pressure measurement system (CardioMEMS, Inc, Atlanta, Ga) in the false lumen adjacent to the primary tear for monitoring aneurysm sac/false lumen pulse pressure after thoracic endovascular aortic repair.

Results: Mean patient age was 57±12 years (range, 30-82 years); 14 patients (28%) were female. Mean aortic diameter was 6.2±1.4 cm. There were no in-hospital/30-day deaths, strokes, or permanent paraplegia/paresis. There were no complications related to compromise of downstream branch vessels arising from the false lumen. Two patients (3.9%) who had preexisting ascending aortic dilation had retrograde acute type A aortic dissection; both were repaired successfully. Median postoperative length of stay was 4 days. Mean follow-up is 27.0±16.5 months (range, 2-60 months). Actuarial overall survival is 77.7% at 60 months with an actuarial aorta-specific survival of 98% over this same time period. Actuarial freedom from reintervention is 77.3% at 60 months. All patients with the EndoSure wireless pressure measurement system exhibited a decrease in aneurysm sac/false lumen pulse pressure indicating a depressurized false lumen. The aneurysm sac/false lumen pulse pressure ratio decreased from 52%±27% at the predischarge measurement to 14%±5% at the latest follow-up reading (P=.029).

Conclusions: Thoracic endovascular aortic repair for chronic type B dissection with associated aneurysm is safe and effective at midterm follow-up. Aneurysm sac/false lumen pulse pressure measurements demonstrate a significant reduction in false lumen endotension, thus ruling out clinically significant persistent retrograde false lumen perfusion and provide proof of concept for a thoracic endovascular aortic repair-based approach. Longer-term follow-up is needed to determine the durability of thoracic endovascular aortic repair for this aortic pathology.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Thoracic / diagnostic imaging
  • Aortic Aneurysm, Thoracic / mortality
  • Aortic Aneurysm, Thoracic / physiopathology
  • Aortic Aneurysm, Thoracic / surgery*
  • Aortic Dissection / diagnostic imaging
  • Aortic Dissection / mortality
  • Aortic Dissection / physiopathology
  • Aortic Dissection / surgery*
  • Aortography / methods
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Blood Vessel Prosthesis Implantation* / instrumentation
  • Blood Vessel Prosthesis Implantation* / mortality
  • Chronic Disease
  • Endovascular Procedures* / adverse effects
  • Endovascular Procedures* / instrumentation
  • Endovascular Procedures* / mortality
  • Female
  • Hemodynamics
  • Humans
  • Kaplan-Meier Estimate
  • Length of Stay
  • Male
  • Middle Aged
  • North Carolina
  • Reoperation
  • Retrospective Studies
  • Time Factors
  • Tomography, X-Ray Computed
  • Transducers, Pressure
  • Treatment Outcome