Heparin-grafted dialysis membrane allows minimal systemic anticoagulation in regular hemodialysis patients: a prospective proof-of-concept study

Hemodial Int. 2013 Apr;17(2):282-93. doi: 10.1111/j.1542-4758.2012.00733.x. Epub 2012 Aug 23.

Abstract

This prospective, multicenter, proof-of-concept study aimed to evaluate the possibility to reduce the ordinary heparin dose and the systemic anti-Xa activity during hemodialysis (HD) sessions using a new heparin-grafted HD membrane. In 45 stable HD patients, the use of a heparin-grafted membrane with the ordinary heparin dose was followed by a stepwise weekly reduction of dose. Reduction was stopped when early signs of clotting (venous pressure, quality of rinse-back) occurred during two out of three weekly HD sessions. Heparin dose was decreased for 67% of patients resulting in the lowering of these patients' anti-Xa activity by 50%. Dose reductions were achieved with both types of heparin (low-molecular-weight heparin: 64 ± 14 to 35 ± 12 IU/kg, P < 0.0001; unfractionated heparin: 82 ± 18 to 46 ± 13 IU/kg, P < 0.0001) resulting in a decrease of anti-Xa activity at dialysis session end (low-molecular-weight heparin: 0.51 ± 0.25 to 0.25 ± 0.11 IU/mL, P < 0.0001; unfractionated heparin: 0.28 ± 0.23 to 0.13 ± 0.07 IU/mL, P < 0.0001). Failure to further decrease heparin dose was related to signs of clotting in blood lines (57% of sessions), in dialyzer (9%), or both (34%). Significant reduction of heparin dose and anti-Xa activity at the end of HD sessions was possible in stable HD patients using heparin-grafted membrane. HD patients who require low anti-Xa activity at the end of HD sessions might benefit from a heparin-grafted membrane to reduce bleeding risk and other heparin adverse events.

Trial registration: ClinicalTrials.gov NCT00781690.

Publication types

  • Clinical Trial
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Anticoagulants / administration & dosage*
  • Blood Coagulation / drug effects*
  • Dose-Response Relationship, Drug
  • Female
  • Heparin, Low-Molecular-Weight / administration & dosage*
  • Humans
  • Kidney Failure, Chronic / blood
  • Kidney Failure, Chronic / therapy
  • Male
  • Membranes, Artificial*
  • Prospective Studies
  • Renal Dialysis / adverse effects
  • Renal Dialysis / instrumentation
  • Renal Dialysis / methods*

Substances

  • Anticoagulants
  • Heparin, Low-Molecular-Weight
  • Membranes, Artificial

Associated data

  • ClinicalTrials.gov/NCT00781690