Clinical value of Flash glucose monitoring in patients with type 1 diabetes treated with continuous subcutaneous insulin infusion

Endocrinol Diabetes Nutr (Engl Ed). 2018 Dec;65(10):556-563. doi: 10.1016/j.endinu.2018.04.003. Epub 2018 Jun 12.
[Article in English, Spanish]

Abstract

Aim: To analyze the clinical impact of the Flash glucose monitoring system in patients with type 1 diabetes mellitus (T1DM) treated with continuous subcutaneous insulin infusion (CSII).

Methods: A 24-week retrospective cohort study in CSII-treated T1DM patients exposed (1:1) to the Flash glucose monitoring system vs. self-monitoring of capillary blood glucose (SMBG). The primary outcome was the difference in hemoglobin A1c (HbA1c) levels between both groups at the end of the study.

Results: Thirty-six patients with a mean age of 38.2 years (range 22-55) and a mean T1DM duration of 20.9±7.8 years, treated with CSII for 7.1±5.4 years, were enrolled into the study. At the end of the study, mean HbA1c levels improved in patients in the Flash group (7.1±0.7 vs. 7.8±1.0, p=0.04). Only the Flash group showed a significant decrease in HbA1c levels of -0.4% (95% CI, -0.6, -0.2; p=0.004) during follow-up. Flash patients captured 93.9% of data through 17.8±9.9 scans daily. In fact, the Flash cohort showed a three-fold increase in daily self-monitoring of glucose, while daily frequency of SMBG decreased during the study (-1.8 tests/24h (95% CI -3, -0.7; p=0.01). No safety issues related to Flash use were recorded.

Conclusions: The Flash glucose monitoring system is a novel approach to improve blood glucose control in CSII-treated T1DM patients. Randomized controlled trials are needed to assess the effectiveness of this system in CSII-treated T1DM patients.

Keywords: Bomba de insulina; Diabetes mellitus tipo 1; Flash; Insulin pump; Interstitial glucose monitoring; Monitorización de la glucosa intersticial; Tratamiento; Treatment; Type 1 diabetes mellitus.

Publication types

  • Evaluation Study
  • Multicenter Study

MeSH terms

  • Adult
  • Biosensing Techniques / instrumentation*
  • Blood Glucose / analysis
  • Blood Glucose Self-Monitoring / instrumentation
  • Blood Glucose Self-Monitoring / methods*
  • Cohort Studies
  • Computer Systems
  • Diabetes Mellitus, Type 1 / blood
  • Diabetes Mellitus, Type 1 / drug therapy*
  • Electrochemical Techniques / instrumentation*
  • Extracellular Fluid / chemistry*
  • Glucose / analysis*
  • Glycated Hemoglobin / analysis
  • Humans
  • Hypoglycemic Agents / administration & dosage
  • Hypoglycemic Agents / therapeutic use*
  • Infusions, Subcutaneous
  • Insulin / administration & dosage
  • Insulin / therapeutic use*
  • Insulin Infusion Systems*
  • Middle Aged
  • Monitoring, Ambulatory / instrumentation
  • Monitoring, Ambulatory / methods*
  • Retrospective Studies

Substances

  • Blood Glucose
  • Glycated Hemoglobin A
  • Hypoglycemic Agents
  • Insulin
  • Glucose