Introduction: Emerging evidence suggests us of real-time continuous glucose monitoring systems (RT-CGM), can assist to improve glucose control in Type 2 Diabetes (T2D) treatment, however the impact of these devices on patients' stress levels and behaviour is poorly understood. This study aimed to examine the effects of RT-CGM on tolerance and acceptability of device wear, stress and diabetes management and motivation to change.
Methods: Twenty adults (10 men, 10 women) with T2D (aged 60.6 ± 8.4 years, BMI 34.2 ± 4.7 kg/m2), were randomised to a low-carbohydrate lifestyle plan whilst wearing a RT-CGM or an 'offline-blinded' (Blinded-CGM) monitoring system continuously for 12 weeks. Outcomes were glycaemic control (HbA1c), weight (kg) perceived stress scale (PSS), CGM device intolerance, acceptability, motivation to change and diabetes management behaviour questionnaires.
Results: Both groups experienced significant reductions in body weight (RT-CGM -7.4 ± 4.5 kg vs. Blinded-CGM -5.5 ± 4.0 kg) and HbA1c (-0.67 ± 0.82% vs. -0.68 ± 0.74%). There were no differences between groups for perceived stress (P = 0.47) or device intolerance at week 6 or 12 (both P > 0.30). However, there was evidence of greater acceptance of CGM in the RT-CGM group at week 12 (P = 0.03), improved blood glucose monitoring behaviour in the RT-CGM group at week 6 and week 12 (P ≤ 0.01), and a significant time x group interaction (P = 0.03) demonstrating improved diabetes self-management behaviours in RT-CGM.
Conclusion: This study provides preliminary evidence of improved behaviours that accompany RT-CGM in the context of diabetes management and glucose self-monitoring. RT-CGM may provide an alternative approach to glucose management in individuals with T2D without resulting in increased disease distress.
Keywords: Acceptability; Continuous glucose monitoring; Tolerance; Type 2 diabetes.
Crown Copyright © 2019. Published by Elsevier B.V. All rights reserved.