Complexity assessment and technical aspect of coronary angiogram and percutaneous coronary intervention following transcatheter aortic valve implantation

Cardiol J. 2022;29(2):197-204. doi: 10.5603/CJ.a2020.0073. Epub 2020 May 21.

Abstract

Background: Performing selective coronary angiogram (CA) and percutaneous coronary intervention (PCI) post transcatheter aortic valve implantation (TAVI) may be challenging with various success rates of coronary ostia engagement.

Methods: Among all patients who underwent CA and/or PCI after TAVI from our single center TAVI registry, ostia cannulation success was reported according to the quality of ostia engagement and artery opacification, and was classified as either selective, partially selective or non-selective but sufficient for diagnosis.

Results: Among the 424 consecutive TAVI procedures performed at the aforementioned institution, 20 (4.7%) CA were performed in 19 (4.5%) patients at a median time of 464 days post TAVI (25-75% IQ: 213-634 days). CA were performed in 7 CoreValve, 9 Evolut R, 1 Evolut PRO and 2 Edwards Sapien 3 devices. Transradial vascular approach was attempted in 9 procedures (45%, right n = 6 and left n = 3) and was successful in 8 (40%) patients. A total of 20 left main artery ostium cannulation were attempted leading to a diagnostic CA in all of them with selective engagement in 65%. Engagement of the right coronary artery in 2 out of 15 attempted cases failed due to a low ostium in conjunction with a high implantation of a CoreValve prosthesis. 11 PCI (55% of CA) including 2 left main lesions were performed. In 4 patients (36.4% of the PCI), an extension catheter was required to engage the left main. All planned PCI were successful.

Conclusions: Post TAVI CA and PCI are challenging but feasible even after supra-annular self-expandable valve implantation.

Keywords: coronary angiogram; percutaneous coronary intervention; self-expandable transcatheter heart valve; transcatheter aortic valve implantation.

MeSH terms

  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / surgery
  • Cardiac Catheterization
  • Coronary Angiography
  • Heart Valve Prosthesis*
  • Humans
  • Percutaneous Coronary Intervention* / adverse effects
  • Prosthesis Design
  • Risk Factors
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Treatment Outcome