Objectives: We evaluated the impact of electronic medical record (EMR)-guided pooled cryoprecipitate dosing vs our previous practice of requiring transfusion medicine (TM) resident approval for every cryoprecipitate transfusion.
Methods: At our hospital, cryoprecipitate pooled from five donors is dosed for adult patients, while single-donor cryoprecipitate is dosed for pediatric patients (defined as patients <50 kg in weight). EMR-based dosing guidance replaced a previously required TM consultation when cryoprecipitate pools were ordered, but a consultation remained required for single-unit orders. Usage was defined as thawed cryoprecipitate; wastage was defined as cryoprecipitate that expired prior to transfusion.
Results: In the 6 months prior to intervention, 178 ± 13 doses of pooled cryoprecipitate were used per month vs 187 ± 15 doses after the intervention (P = .68). Wastage of pooled cryoprecipitate increased from 7.7% ± 1.5% to 12.7% ± 1.4% (P = .038). There was no change in wastage of pediatric cryoprecipitate doses during the study period. These trends remained unchanged for a full year postimplementation.
Conclusions: Electronic dosing guidance resulted in similar cryoprecipitate usage as TM auditing. Increased wastage may result from reduced TM oversight. Product wastage should be balanced against the possibility that real-time audits could delay a lifesaving therapy.
Keywords: Cryoprecipitate; Electronic medical records; Patient blood management.
© American Society for Clinical Pathology, 2020. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.