Transthoracic echocardiographic power motion tissue imaging of an intracardiac tumor that could not be seen with conventional transthoracic echocardiographic recordings
J Am Soc Echocardiogr. 1998 Oct;11(10):989-91.
doi: 10.1016/s0894-7317(98)70144-0.
Power motion imaging allows interrogation of low-velocity tissue. By means of power motion imaging with 2 different late-model echographs we identified an intra-atrial tumor that was undetectable on conventional transthoracic echocardiograms.
Publication types
Case Reports
MeSH terms
Aged
Echocardiography, Transesophageal
Heart Neoplasms / diagnostic imaging*
Humans
Image Processing, Computer-Assisted
Lymphoma, Large B-Cell, Diffuse / diagnostic imaging*